{"id":1999,"date":"2025-03-12T15:37:57","date_gmt":"2025-03-12T14:37:57","guid":{"rendered":"https:\/\/sita-slovensko.com\/aplikacia\/kontrola-povrchu-a-dielov\/"},"modified":"2026-10-29T05:30:50","modified_gmt":"2026-10-29T04:30:50","slug":"kontrola-povrchu-a-dilu","status":"publish","type":"aplikacia","link":"https:\/\/sita-slovensko.com\/cs\/aplikacia\/kontrola-povrchu-a-dilu\/","title":{"rendered":"Kontrola povrchu a\u00a0d\u00edl\u016f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">P\u0159ilnavost laku, pevnost lepen\u00e9ho spoje a kvalita svaru se rozhoduj\u00ed je\u0161t\u011b p\u0159ed nan\u00e1\u0161en\u00edm \u2013 na \u010distot\u011b a sm\u00e1\u010divosti povrchu. P\u0159\u00edstroje SITA m\u011b\u0159\u00ed zbytky oleje, separa\u010dn\u00edch prost\u0159edk\u016f a aktivaci povrchu p\u0159\u00edmo na d\u00edlu, bez rozpou\u0161t\u011bdel a bez laborato\u0159e.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Jak\u00e9 probl\u00e9my \u0159e\u0161\u00edme<\/h2>\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Zbytky oleje a maziva p\u0159ed lakov\u00e1n\u00edm, lepen\u00edm a sva\u0159ov\u00e1n\u00edm<\/strong> \u2013 ru\u010dn\u00ed <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-cleanospector\/\">SITA CleanoSpector<\/a> zm\u011b\u0159\u00ed filmovou \u010distotu b\u011bhem sekund.<\/li>\n\n<li><strong>Separa\u010dn\u00ed prost\u0159edky na hlin\u00edkov\u00fdch odlitc\u00edch p\u0159ed lepen\u00edm<\/strong> \u2013 plo\u0161n\u00e9 skenov\u00e1n\u00ed <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-fluoscan-3d\/\">SITA FluoScan 3D<\/a>.<\/li>\n\n<li><strong>Kontrola \u010distoty dr\u00e1tu, trubek a p\u00e1su p\u0159\u00edmo v lince<\/strong> \u2013 inline senzor <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-clean-line-ci\/\">SITA clean line CI<\/a>.<\/li>\n\n<li><strong>Sm\u00e1\u010divost po plazm\u011b, kor\u00f3n\u011b nebo \u010di\u0161t\u011bn\u00ed<\/strong> \u2013 m\u011b\u0159en\u00ed kontaktn\u00edho \u00fahlu <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-surfaspector\/\">SITA SurfaSpector<\/a> m\u00edsto testovac\u00edch inkoust\u016f.<\/li>\n\n<li><strong>Stanoven\u00ed limitn\u00edch hodnot \u010distoty<\/strong> pro kontroln\u00ed pl\u00e1n a audit \u2013 pom\u016f\u017eeme p\u0159i uveden\u00ed p\u0159\u00edstroje.<\/li>\n<\/ul>\n\n\n<h2 class=\"wp-block-heading\">Pro koho<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Lakovny a KTL, lepen\u00ed v automobilov\u00e9m a leteck\u00e9m pr\u016fmyslu, v\u00fdroba bateri\u00ed a elektroniky, tlakov\u00e9 lit\u00ed hlin\u00edku, zdravotnick\u00e1 technika, kovoobr\u00e1b\u011bn\u00ed. D\u00edly zm\u011b\u0159\u00edme u v\u00e1s nebo v na\u0161\u00ed laborato\u0159i \u2013 p\u0159ineste 5 d\u00edl\u016f a uvid\u00edte rozd\u00edl.<\/p>\n\n\n<h2 class=\"wp-block-heading\">\u010cast\u00e9 dotazy<\/h2>\n\n\n<style>.faq-q{margin:22px 0 6px !important;font-size:1.05em;line-height:1.4}.faq-a{position:relative;padding-left:1.7em !important;margin:0 0 6px !important}.faq-a::before{content:\"\\2794\";position:absolute;left:0;top:0;color:#c8102e;font-weight:700}<\/style>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Pro\u010d se lak nebo lepidlo odlupuje z d\u00edl\u016f, kter\u00e9 vypadaj\u00ed \u010dist\u011b?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Nej\u010dast\u011bji kv\u016fli neviditeln\u00e9mu filmu oleje, chladic\u00ed emulze nebo separa\u010dn\u00edho prost\u0159edku. SITA CleanoSpector jej zm\u011b\u0159\u00ed UV fluorescenc\u00ed b\u011bhem sekund a d\u00e1 hodnotu v RFU, podle kter\u00e9 d\u00edl uvoln\u00edte nebo zastav\u00edte.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak\u00fd je rozd\u00edl mezi filmovou a \u010d\u00e1sticovou \u010distotou?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">\u010c\u00e1sticov\u00e1 \u010distota podle VDA 19.1 \u0159e\u0161\u00ed \u010d\u00e1stice; filmov\u00e1 \u010distota \u0159e\u0161\u00ed tenk\u00e9 organick\u00e9 filmy, kter\u00e9 rozhoduj\u00ed o p\u0159ilnavosti laku a lepidla. P\u0159\u00edstroje SITA m\u011b\u0159\u00ed filmovou \u010distotu.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak stanov\u00edm limit \u010distoty pro sv\u016fj proces?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Zm\u011b\u0159te \u010dist\u00e9 referen\u010dn\u00ed d\u00edly a d\u00edly s reklamac\u00ed; rozd\u00edl hodnot RFU ur\u010d\u00ed z\u00e1sahov\u00fd limit. P\u0159i uveden\u00ed p\u0159\u00edstroje limit nastav\u00edme spole\u010dn\u011b s v\u00e1mi.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak ov\u011b\u0159\u00edm \u00fa\u010dinnost plazmy nebo kor\u00f3ny p\u0159ed lepen\u00edm?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">M\u011b\u0159en\u00edm kontaktn\u00edho \u00fahlu kapky vody p\u0159\u00edstrojem SITA SurfaSpector p\u0159\u00edmo na d\u00edlu (5 \u2013 175\u00b0, rozli\u0161en\u00ed 0,1\u00b0) \u2013 objektivn\u00ed \u010d\u00edslo m\u00edsto testovac\u00edch inkoust\u016f.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Lze kontrolu \u010distoty automatizovat?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Ano: SITA FluoScan 3D skenuje cel\u00e9 d\u00edly v laborato\u0159i nebo v\u00fdrob\u011b a SITA clean line CI m\u011b\u0159\u00ed inline na dr\u00e1tu, p\u00e1su nebo d\u00edlech na dopravn\u00edku.<\/p>\n\n\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"inLanguage\":\"cs-CZ\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Pro\u010d se lak nebo lepidlo odlupuje z d\u00edl\u016f, kter\u00e9 vypadaj\u00ed \u010dist\u011b?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Nej\u010dast\u011bji kv\u016fli neviditeln\u00e9mu filmu oleje, chladic\u00ed emulze nebo separa\u010dn\u00edho prost\u0159edku. SITA CleanoSpector jej zm\u011b\u0159\u00ed UV fluorescenc\u00ed b\u011bhem sekund a d\u00e1 hodnotu v RFU, podle kter\u00e9 d\u00edl uvoln\u00edte nebo zastav\u00edte.\"}},{\"@type\":\"Question\",\"name\":\"Jak\u00fd je rozd\u00edl mezi filmovou a \u010d\u00e1sticovou \u010distotou?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"\u010c\u00e1sticov\u00e1 \u010distota podle VDA 19.1 \u0159e\u0161\u00ed \u010d\u00e1stice; filmov\u00e1 \u010distota \u0159e\u0161\u00ed tenk\u00e9 organick\u00e9 filmy, kter\u00e9 rozhoduj\u00ed o p\u0159ilnavosti laku a lepidla. P\u0159\u00edstroje SITA m\u011b\u0159\u00ed filmovou \u010distotu.\"}},{\"@type\":\"Question\",\"name\":\"Jak stanov\u00edm limit \u010distoty pro sv\u016fj proces?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Zm\u011b\u0159te \u010dist\u00e9 referen\u010dn\u00ed d\u00edly a d\u00edly s reklamac\u00ed; rozd\u00edl hodnot RFU ur\u010d\u00ed z\u00e1sahov\u00fd limit. P\u0159i uveden\u00ed p\u0159\u00edstroje limit nastav\u00edme spole\u010dn\u011b s v\u00e1mi.\"}},{\"@type\":\"Question\",\"name\":\"Jak ov\u011b\u0159\u00edm \u00fa\u010dinnost plazmy nebo kor\u00f3ny p\u0159ed lepen\u00edm?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"M\u011b\u0159en\u00edm kontaktn\u00edho \u00fahlu kapky vody p\u0159\u00edstrojem SITA SurfaSpector p\u0159\u00edmo na d\u00edlu (5 \u2013 175\u00b0, rozli\u0161en\u00ed 0,1\u00b0) \u2013 objektivn\u00ed \u010d\u00edslo m\u00edsto testovac\u00edch inkoust\u016f.\"}},{\"@type\":\"Question\",\"name\":\"Lze kontrolu \u010distoty automatizovat?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ano: SITA FluoScan 3D skenuje cel\u00e9 d\u00edly v laborato\u0159i nebo v\u00fdrob\u011b a SITA clean line CI m\u011b\u0159\u00ed inline na dr\u00e1tu, p\u00e1su nebo d\u00edlech na dopravn\u00edku.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u010cistota a sm\u00e1\u010divost povrch\u016f po \u010di\u0161t\u011bn\u00ed a aktivaci m\u00e1 v\u00fdznamn\u00fd vliv na kvalitu proces\u016f lepen\u00ed, sva\u0159ov\u00e1n\u00ed, lakov\u00e1n\u00ed a n\u00e1t\u011br\u016f. Pomoc\u00ed na\u0161\u00ed technologie m\u011b\u0159en\u00ed fluorescence m\u016f\u017eete zkontrolovat filmov\u00e9 zne\u010di\u0161t\u011bn\u00ed na povr\u0161\u00edch d\u00edl\u016f. SITA SurfaSpector kontroluje sm\u00e1\u010divost m\u011b\u0159en\u00edm kontaktn\u00edho \u00fahlu.<\/p>\n","protected":false},"featured_media":1710,"template":"","meta":{"_acf_changed":false},"class_list":["post-1999","aplikacia","type-aplikacia","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/aplikacia\/1999","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/aplikacia"}],"about":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/types\/aplikacia"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/media\/1710"}],"wp:attachment":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/media?parent=1999"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}