{"id":1976,"date":"2025-03-12T14:09:15","date_gmt":"2025-03-12T13:09:15","guid":{"rendered":"https:\/\/sita-slovensko.com\/aplikacia\/kontrola-kapalin-a-medii\/"},"modified":"2026-10-29T05:30:48","modified_gmt":"2026-10-29T04:30:48","slug":"kontrola-kapalin-a-medii","status":"publish","type":"aplikacia","link":"https:\/\/sita-slovensko.com\/cs\/aplikacia\/kontrola-kapalin-a-medii\/","title":{"rendered":"Kontrola kapalin a m\u00e9di\u00ed"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Myc\u00ed linka funguje jen tak dob\u0159e, jak dobr\u00e1 je jej\u00ed l\u00e1ze\u0148. Koncentrace tenzid\u016f kles\u00e1, olej se hromad\u00ed a p\u011bna blokuje \u010derpadla \u2013 v\u00fdsledkem jsou nedostate\u010dn\u011b odma\u0161t\u011bn\u00e9 d\u00edly, reklamace p\u0159ilnavosti laku a zbyte\u010dn\u011b vym\u011b\u0148ovan\u00e1 chemie. P\u0159\u00edstroje SITA m\u011b\u0159\u00ed stav procesn\u00edch kapalin p\u0159\u00edmo ve v\u00fdrob\u011b: povrchov\u00e9 nap\u011bt\u00ed, zaolejov\u00e1n\u00ed a p\u011bnivost.<\/p>\n\n\n<h2 class=\"wp-block-heading\">Jak\u00e9 probl\u00e9my \u0159e\u0161\u00edme<\/h2>\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Kdy doplnit nebo vym\u011bnit odma\u0161\u0165ovac\u00ed l\u00e1ze\u0148<\/strong> \u2013 m\u011b\u0159en\u00ed dynamick\u00e9ho povrchov\u00e9ho nap\u011bt\u00ed ru\u010dn\u00edm tenziometrem <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-dynotester\/\">SITA DynoTester+<\/a> nebo online v lince pomoc\u00ed <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-clean-line-st\/\">SITA clean line ST<\/a>.<\/li>\n\n<li><strong>Zaolejov\u00e1n\u00ed myc\u00edch a oplachov\u00fdch l\u00e1zn\u00ed<\/strong> \u2013 fluorescen\u010dn\u00ed m\u011b\u0159en\u00ed oleje v l\u00e1zni p\u0159\u00edstrojem <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-conspector\/\">SITA ConSpector<\/a> nebo nep\u0159etr\u017eit\u011b se <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-clean-line-bc\/\">SITA clean line BC<\/a>.<\/li>\n\n<li><strong>Kontrola sm\u00e1\u010dedel v galvanick\u00fdch l\u00e1zn\u00edch, fosf\u00e1tov\u00e1n\u00ed a lakovn\u00e1ch<\/strong> \u2013 rychl\u00e1 kontrola koncentrace tenzid\u016f bez laborato\u0159e.<\/li>\n\n<li><strong>P\u011bna v lince, chladic\u00edch emulz\u00edch a \u010distic\u00edch prost\u0159edc\u00edch<\/strong> \u2013 objektivn\u00ed testov\u00e1n\u00ed p\u011bnivosti a odp\u011b\u0148ova\u010d\u016f se <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-foamtester\/\">SITA FoamTester<\/a>.<\/li>\n\n<li><strong>V\u00fdvoj a kontrola kvality chemie<\/strong> \u2013 laboratorn\u00ed tenziometry <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-pro-line-t15\/\">pro line t15+<\/a> a <a href=\"https:\/\/sita-slovensko.com\/cs\/produkt\/sita-science-line-t100\/\">science line t100<\/a> pro koncentra\u010dn\u00ed k\u0159ivky a kinetiku tenzid\u016f.<\/li>\n<\/ul>\n\n\n<h2 class=\"wp-block-heading\">Pro koho<\/h2>\n\n\n<p class=\"wp-block-paragraph\">Myc\u00ed a odma\u0161\u0165ovac\u00ed linky v automobilov\u00e9m pr\u016fmyslu a kovoobr\u00e1b\u011bn\u00ed, galvanovny, lakovny a p\u0159ed\u00fapravy p\u0159ed KTL, v\u00fdrobci a dodavatel\u00e9 pr\u016fmyslov\u00e9 chemie, elektronika a zdravotnick\u00e1 technika. P\u0159\u00edstroje v\u00e1m uk\u00e1\u017eeme p\u0159\u00edmo na va\u0161\u00ed lince \u2013 m\u011b\u0159en\u00ed na m\u00edst\u011b je zdarma.<\/p>\n\n\n<h2 class=\"wp-block-heading\">\u010cast\u00e9 dotazy<\/h2>\n\n\n<style>.faq-q{margin:22px 0 6px !important;font-size:1.05em;line-height:1.4}.faq-a{position:relative;padding-left:1.7em !important;margin:0 0 6px !important}.faq-a::before{content:\"\\2794\";position:absolute;left:0;top:0;color:#c8102e;font-weight:700}<\/style>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak pozn\u00e1m, kdy je t\u0159eba vym\u011bnit odma\u0161\u0165ovac\u00ed l\u00e1ze\u0148?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Zm\u011b\u0159te dynamick\u00e9 povrchov\u00e9 nap\u011bt\u00ed l\u00e1zn\u011b ru\u010dn\u00edm tenziometrem SITA DynoTester+ a porovnejte je s referen\u010dn\u00ed hodnotou \u010derstv\u00e9 l\u00e1zn\u011b. R\u016fst hodnoty znamen\u00e1 pokles aktivn\u00edch tenzid\u016f \u2013 l\u00e1ze\u0148 dopl\u0148te; pokud hodnota po dopln\u011bn\u00ed nekles\u00e1, l\u00e1ze\u0148 je zaolejovan\u00e1 a je t\u0159eba ji vym\u011bnit.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Pro\u010d titrace neuk\u00e1\u017ee stav odma\u0161\u0165ovac\u00ed l\u00e1zn\u011b?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Titrace m\u011b\u0159\u00ed celkovou alkalitu, ne aktivn\u00ed tenzidy. Odma\u0161\u0165ovac\u00ed \u00fa\u010dinek z\u00e1vis\u00ed na tenzidech, proto se stav l\u00e1zn\u011b sleduje m\u011b\u0159en\u00edm povrchov\u00e9ho nap\u011bt\u00ed; titrace z\u016fst\u00e1v\u00e1 jako dopln\u011bk.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak zjist\u00edm zaolejov\u00e1n\u00ed myc\u00ed nebo oplachov\u00e9 l\u00e1zn\u011b?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Fluorescen\u010dn\u00ed p\u0159\u00edstroj SITA ConSpector zm\u011b\u0159\u00ed mno\u017estv\u00ed oleje a maziva v l\u00e1zni za p\u00e1r sekund; pro nep\u0159etr\u017eit\u00e9 sledov\u00e1n\u00ed v lince slou\u017e\u00ed SITA clean line BC.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Lze l\u00e1ze\u0148 sledovat automaticky?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">Ano. Online tenziometr SITA clean line ST m\u011b\u0159\u00ed povrchov\u00e9 nap\u011bt\u00ed p\u0159\u00edmo v lince a \u0159\u00edd\u00ed d\u00e1vkov\u00e1n\u00ed odma\u0161\u0165ova\u010de podle skute\u010dn\u00e9 koncentrace tenzid\u016f, ne podle \u010dasu nebo po\u010dtu d\u00edl\u016f.<\/p>\n\n\n<p class=\"faq-q wp-block-paragraph\"><strong>Jak otestuji p\u011bnivost \u010distic\u00edho prost\u0159edku nebo \u00fa\u010dinnost odp\u011b\u0148ova\u010de?<\/strong><\/p>\n\n\n<p class=\"faq-a wp-block-paragraph\">SITA FoamTester vytvo\u0159\u00ed p\u011bnu za definovan\u00fdch podm\u00ednek a zm\u011b\u0159\u00ed objem, rozpad a strukturu p\u011bny, tak\u017ee dva produkty nebo d\u00e1vky odp\u011b\u0148ova\u010de porovn\u00e1te \u010d\u00edsly.<\/p>\n\n\n<script type=\"application\/ld+json\">{\"@context\":\"https:\/\/schema.org\",\"@type\":\"FAQPage\",\"inLanguage\":\"cs-CZ\",\"mainEntity\":[{\"@type\":\"Question\",\"name\":\"Jak pozn\u00e1m, kdy je t\u0159eba vym\u011bnit odma\u0161\u0165ovac\u00ed l\u00e1ze\u0148?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Zm\u011b\u0159te dynamick\u00e9 povrchov\u00e9 nap\u011bt\u00ed l\u00e1zn\u011b ru\u010dn\u00edm tenziometrem SITA DynoTester+ a porovnejte je s referen\u010dn\u00ed hodnotou \u010derstv\u00e9 l\u00e1zn\u011b. R\u016fst hodnoty znamen\u00e1 pokles aktivn\u00edch tenzid\u016f \u2013 l\u00e1ze\u0148 dopl\u0148te; pokud hodnota po dopln\u011bn\u00ed nekles\u00e1, l\u00e1ze\u0148 je zaolejovan\u00e1 a je t\u0159eba ji vym\u011bnit.\"}},{\"@type\":\"Question\",\"name\":\"Pro\u010d titrace neuk\u00e1\u017ee stav odma\u0161\u0165ovac\u00ed l\u00e1zn\u011b?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Titrace m\u011b\u0159\u00ed celkovou alkalitu, ne aktivn\u00ed tenzidy. Odma\u0161\u0165ovac\u00ed \u00fa\u010dinek z\u00e1vis\u00ed na tenzidech, proto se stav l\u00e1zn\u011b sleduje m\u011b\u0159en\u00edm povrchov\u00e9ho nap\u011bt\u00ed; titrace z\u016fst\u00e1v\u00e1 jako dopln\u011bk.\"}},{\"@type\":\"Question\",\"name\":\"Jak zjist\u00edm zaolejov\u00e1n\u00ed myc\u00ed nebo oplachov\u00e9 l\u00e1zn\u011b?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Fluorescen\u010dn\u00ed p\u0159\u00edstroj SITA ConSpector zm\u011b\u0159\u00ed mno\u017estv\u00ed oleje a maziva v l\u00e1zni za p\u00e1r sekund; pro nep\u0159etr\u017eit\u00e9 sledov\u00e1n\u00ed v lince slou\u017e\u00ed SITA clean line BC.\"}},{\"@type\":\"Question\",\"name\":\"Lze l\u00e1ze\u0148 sledovat automaticky?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"Ano. Online tenziometr SITA clean line ST m\u011b\u0159\u00ed povrchov\u00e9 nap\u011bt\u00ed p\u0159\u00edmo v lince a \u0159\u00edd\u00ed d\u00e1vkov\u00e1n\u00ed odma\u0161\u0165ova\u010de podle skute\u010dn\u00e9 koncentrace tenzid\u016f, ne podle \u010dasu nebo po\u010dtu d\u00edl\u016f.\"}},{\"@type\":\"Question\",\"name\":\"Jak otestuji p\u011bnivost \u010distic\u00edho prost\u0159edku nebo \u00fa\u010dinnost odp\u011b\u0148ova\u010de?\",\"acceptedAnswer\":{\"@type\":\"Answer\",\"text\":\"SITA FoamTester vytvo\u0159\u00ed p\u011bnu za definovan\u00fdch podm\u00ednek a zm\u011b\u0159\u00ed objem, rozpad a strukturu p\u011bny, tak\u017ee dva produkty nebo d\u00e1vky odp\u011b\u0148ova\u010de porovn\u00e1te \u010d\u00edsly.\"}}]}<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Povrchov\u011b aktivn\u00ed l\u00e1tky v technick\u00fdch procesech zp\u016fsobuj\u00ed sm\u00e1\u010den\u00ed povrchu a dal\u0161\u00ed \u00fa\u010dinky. Pomoc\u00ed tenzometr\u016f SITA lze ur\u010dit koncentraci povrchov\u011b aktivn\u00ed l\u00e1tky a dynamick\u00e9 povrchov\u00e9 nap\u011bt\u00ed. Kontaminace v \u010distic\u00edch l\u00e1zn\u00edch zp\u016fsoben\u00e1 oleji a tuky se monitoruje m\u011b\u0159en\u00edm fluorescence kapaliny. SITA FoamTester lze pou\u017e\u00edt pro testov\u00e1n\u00ed, kontrolu a sledov\u00e1n\u00ed p\u011bniv\u00fdch vlastnost\u00ed kapalin obsahuj\u00edc\u00edch povrchov\u011b aktivn\u00ed l\u00e1tky.   <\/p>\n","protected":false},"featured_media":1711,"template":"","meta":{"_acf_changed":false},"class_list":["post-1976","aplikacia","type-aplikacia","status-publish","has-post-thumbnail","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/aplikacia\/1976","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/aplikacia"}],"about":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/types\/aplikacia"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/media\/1711"}],"wp:attachment":[{"href":"https:\/\/sita-slovensko.com\/cs\/wp-json\/wp\/v2\/media?parent=1976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}